Water flowmeters (water meters) Floukor DRC-4A, DRC-4B, etc.

According to the type of information issued , flowmeters have 2 versions:
DRK-4A - has only a pulse output; during the time between two pulses, a given volume of liquid is pumped through the pipeline, called the pulse price;
DRK-4V - has a pulse output, an indicator of accumulated volume, instantaneous flow and operating time, as well as a current output signal of 0-5 or 4-20 mA and a built-in power supply operating from a 220 V, 50 Hz network. In addition, DRK-4B flowmeters have an archive with hourly registration of the accumulated volume for 46 days, an RS-232 port for communication with a computer and an RS-485 port (optional).
According to the diameter of the pipeline in which the measurement is made, the flowmeters have two versions:
- DRK-4A (B)1 - designed for installation on pipelines with an internal diameter from 80 to 350 mm.
- DRK-4A (B)2 - designed for installation on pipelines with an internal diameter of more than 300 mm.
- Safety requirements: sensors belong to class 0 according to GOST 12.2.007.0-75
- Protection against dust and water penetration - IP54 according to GOST 14254-80
- Relative humidity (at a temperature of 35 ° C) - up to 95%
- Ambient air temperature from -40 to +50 o C
- The storage time of information in the counters of accumulated volume and operating time with power off is at least 10 years
- The total average service life of the meters is 8 years
- The devices are designed to measure the volume of liquid with parameters:
- Working fluid temperature from +1 to +150 o C
- Working fluid pressure up to 2.5 MPa (25 kgf/cm2)
- The viscosity of the liquid is up to 2.0 cSt
- The internal diameter of the pipeline is from 80 to 4000 mm.
- The minimum measured flow rate (on pipes with an internal diameter of 80 mm.) is 2.7 m3/h
- The maximum measured flow rate (on pipes with an internal diameter of 4000 mm.) is 452000 m3/h
- Limits of permissible relative error in measuring volume and flow by pulse signal and indicator: ± 1.5%
- Limits of the measured reduced error of flow measurement by Current signal: ± 1.5%
- The length of the straight section in front of the acoustic transducers:
- not less than 5d (if a round knee, a fully open gate valve or a conical narrowing with an angle of no more than 30 o are located in front of them)
- at least 10D in other cases ( there should be a free pipe along the pipe axis in front of the primary converter, which does not have elements protruding inside - temperature sensors, pressure gauges, etc.)
- The length of the straight section after the acoustic transducers is at least 2Du
- The sensors have a pulse output signal (all versions),
which can be transmitted as current pulses or removed from
the optocoupler output, as well as a DC output signal
proportional to the instantaneous flow rate (only DRC-4V).
Signal Parameters:
- Pulse
- pulse duration - at least 125 ms
- the amplitude is (10 ± 3) mA with a load of no more than 500 ohms
- Optocoupler output
- pulse duration - at least 250 ms
- voltage in the output circuit - no more than 30 V
- the value of the current pulse in the output circuit is not more than 100 mA
- Parameters of the current output signal
- 0-5 mA with a load resistance of no more than 2 kOhm
- 4-20 mA with a load resistance of no more than 500 ohms
- The DRK-4V devices are powered from an alternating current network with a voltage of (187... 242) V and a frequency of 50 ± 1 Hz. Consumed power not more than 20 VA
- The DRK-4A devices are powered from a stabilized DC source (11.5...15) V at a load of up to 500 mA. The resistance of the communication line is not more than 5 ohms per core
All Floukor products
About Floukor
-
COMMERCIAL ACCOUNTING
Improving the quality of measurements. Reducing the need for expensive maintenance. Reducing the number of additional equipment. Long-term stability of measurements. Reduce downtime. -
ACCURATE ACCOUNTING OF LIQUIDS
Reduction of the measurement error. Lower maintenance costs. Improving the reliability of measurements. A wide range of measurements. No requirements for straight sections. -
service
Technical support, repair of devices, verification of devices, telephone consultations, visiting the enterprise to customers for prompt troubleshooting of possible problems
NEW TECHNOLOGIES GROUP
Contact us or your local dealer for more information on certifications, features, reviews, pricing, stock availability and delivery terms for Floukor products.
Reply guaranteed within 8 business hours
- (727)345-47-04
- (3955)60-70-56
- (8182)63-90-72
- (8512)99-46-04
- (3852)73-04-60
- (4722)40-23-64
- (4162)22-76-07
- (4832)59-03-52
- (8352)28-53-07
- (351)202-03-61
- (8202)49-02-64
- (3022)38-34-83
- (395)279-98-46
- (4932)77-34-06
- (3412)26-03-58
- (4012)72-03-81
- (4842)92-23-67
- (843)206-01-48
- (3842)65-04-62
- (4212)92-98-04
- (8332)68-02-04
- (4966)23-41-49
- (4942)77-07-48
- (861)203-40-90
- (391)204-63-61
- (3522)50-90-47
- (4712)77-13-04
- (4742)52-20-81
- (3519)55-03-13
- (375)257-127-884
- (495)268-04-70
- (8152)59-64-93
- (8552)20-53-41
- (831)429-08-12
- (3843)20-46-81
- (383)227-86-73
- (3496)41-32-12
- (3812)21-46-40
- (4862)44-53-42
- (3532)37-68-04
- (8412)22-31-16
- (342)205-81-47
- (8142)55-98-37
- (8112)59-10-37
- (863)308-18-15
- (4912)46-61-64
- (812)309-46-40
- (846)206-03-16
- (8342)22-96-24
- (845)249-38-78
- (8692)22-31-93
- (3652)67-13-56
- (4812)29-41-54
- (862)225-72-31
- (8652)20-65-13
- (3462)77-98-35
- (8212)25-95-17
- (4752)50-40-97
- (998)71-205-18-59
- (8482)63-91-07
- (3822)98-41-53
- (4872)33-79-87
- (4822)63-31-35
- (3452)66-21-18
- (347)229-48-12
- (3012)59-97-51
- (8422)24-23-59
- (8672)28-90-48
- (4922)49-43-18
- (423)249-28-31
- (844)278-03-48
- (8172)26-41-59
- (473)204-51-73
- (4112)23-90-97
- (4852)69-52-93
- (343)384-55-89