Flow converters Floukor DRC-B1, DRC-B2, DRC-B3, etc.

The DRC converter is available in four versions:
DRC-B1, DRC-VM has a pulse output. During the time between the two pulses, a given volume of liquid is pumped through the pipeline. In the future, this volume is referred to as the impulse price. In addition, the DRC-B1 is equipped with an indicator of accumulated volume, instantaneous consumption and operating time.
DRC-B2 has only a pulse output.
DRK-V3 has a pulse output, an indicator of accumulated volume, consumption and operating time.
Technical specifications
- The converter belongs to group 2 type 1 according to GOST 27.003, to recoverable repaired single-channel multifunctional products
- According to the method of electrical protection, the converters belong to class 01 according to GOST 12.2.007.0. Safety requirements according to OST 25.977, section 2
- In terms of environmental protection , the converter complies with IP-54 according to GOST 15150-69
- In terms of resistance to mechanical influences, the converter corresponds to the N4 version according to GOST 12997
- By ambient temperature and humidity the converter belongs to group D3 according to GOST 12997-84
- Ambient air temperature from -40 to +50 o C
- Relative humidity (at a temperature of 35 ° C) - up to 95%
- Working fluid parameters:
- Working fluid temperature - from +1 to +150 o C
- Working fluid pressure - up to 1.6 MPa
- The viscosity of the liquid is not more than 2.0 cSt
- Nominal diameters of pipelines - 25; 32; 50; 80; 100 mm
- Measurement limits:
- Minimum (at Dw = 25mm.) - 0.2 m3/h
- Maximum (at Dw = 100mm.) - 200 3/h
- Output signals:
- pulse signal
- indicator of accumulated volume, instantaneous consumption and time developments
- Type of pulse signal:
- current pulse
- optocoupler
- The resistance in the signal circuit "current pulse" - no more than 500 ohms
- The pulse duration at the "current pulse" and "optocoupler" outputs is at least 100 ms. In agreement with the customer, it is allowed manufacture of devices with shorter and longer pulse durations (50, 200 ms).
- The DRC-B1 and DRC-B2 converters are powered from a DC source. The current value is not more than 150 mA, the voltage is 18 ... 24V, the voltage ripple is not more than 200 mV.
- The bit depth of the accumulated volume counter is 8 decimal places.
- The storage time of information in the counters of accumulated volume and operating time with power off is at least 10 years.
The warranty period of operation is 18 months from the date of commissioning of the converter .
The warranty period of storage is 6 months from the date of manufacture
- Liquid flow rate converters correlation DRC-B1, DRC-B2, DRC-B3. User Manual
- The liquid flow converter is a correlation vortex low-consumption DRC-VM. User Manual
- Liquid flow rate converters correlation vortex DRK-V. Description of the type of measuring instrument.
- Liquid flowmeters correlation vortex DRC-V. Description of the type of measuring instrument.
All Floukor products
About Floukor
-
COMMERCIAL ACCOUNTING
Improving the quality of measurements. Reducing the need for expensive maintenance. Reducing the number of additional equipment. Long-term stability of measurements. Reduce downtime. -
ACCURATE ACCOUNTING OF LIQUIDS
Reduction of the measurement error. Lower maintenance costs. Improving the reliability of measurements. A wide range of measurements. No requirements for straight sections. -
service
Technical support, repair of devices, verification of devices, telephone consultations, visiting the enterprise to customers for prompt troubleshooting of possible problems
NEW TECHNOLOGIES GROUP
Contact us or your local dealer for more information on certifications, features, reviews, pricing, stock availability and delivery terms for Floukor products.
Reply guaranteed within 8 business hours
- (727)345-47-04
- (3955)60-70-56
- (8182)63-90-72
- (8512)99-46-04
- (3852)73-04-60
- (4722)40-23-64
- (4162)22-76-07
- (4832)59-03-52
- (8352)28-53-07
- (351)202-03-61
- (8202)49-02-64
- (3022)38-34-83
- (395)279-98-46
- (4932)77-34-06
- (3412)26-03-58
- (4012)72-03-81
- (4842)92-23-67
- (843)206-01-48
- (3842)65-04-62
- (4212)92-98-04
- (8332)68-02-04
- (4966)23-41-49
- (4942)77-07-48
- (861)203-40-90
- (391)204-63-61
- (3522)50-90-47
- (4712)77-13-04
- (4742)52-20-81
- (3519)55-03-13
- (375)257-127-884
- (495)268-04-70
- (8152)59-64-93
- (8552)20-53-41
- (831)429-08-12
- (3843)20-46-81
- (383)227-86-73
- (3496)41-32-12
- (3812)21-46-40
- (4862)44-53-42
- (3532)37-68-04
- (8412)22-31-16
- (342)205-81-47
- (8142)55-98-37
- (8112)59-10-37
- (863)308-18-15
- (4912)46-61-64
- (812)309-46-40
- (846)206-03-16
- (8342)22-96-24
- (845)249-38-78
- (8692)22-31-93
- (3652)67-13-56
- (4812)29-41-54
- (862)225-72-31
- (8652)20-65-13
- (3462)77-98-35
- (8212)25-95-17
- (4752)50-40-97
- (998)71-205-18-59
- (8482)63-91-07
- (3822)98-41-53
- (4872)33-79-87
- (4822)63-31-35
- (3452)66-21-18
- (347)229-48-12
- (3012)59-97-51
- (8422)24-23-59
- (8672)28-90-48
- (4922)49-43-18
- (423)249-28-31
- (844)278-03-48
- (8172)26-41-59
- (473)204-51-73
- (4112)23-90-97
- (4852)69-52-93
- (343)384-55-89