Shipping throughout Russia and to other countries

The DRC 3 correlation water flow sensors are available in five versions:

  • DRK-3A - has only a pulse output; during the time between two pulses, a given volume of liquid is pumped through the pipeline, called the pulse price;
  • DRK-3B - has, along with a pulse output , an indicator of accumulated volume, instantaneous consumption and operating time;
  • DRK-3V - has a pulse output, an indicator of accumulated volume, instantaneous flow and operating time, as well as a current output signal of 0-5 or 4-20 mA and a built-in power supply operating from a 220 V, 50 Hz network.
    It is possible to perform DRK-3V with a current output signal without an indicator and with an indicator without a current output signal.

According to the diameter of the pipeline in which the measurement is made, the devices have two versions:

  • DRK-3X1 - designed for installation on pipelines with an internal diameter from 80 to 350 mm.
  • DRK-3X2 - designed for installation on pipelines with an internal diameter of more than 300 mm.
Technical specifications
  • Safety requirements: sensors belong to class 0 according to GOST 12.2.007.0-75
  • Protection against dust and water penetration - IP54 according to GOST 14254-80
  • Relative humidity (at a temperature of 35 ° C) - up to 95%
  • Ambient air temperature from -40 to +50 o C
  • The storage time of information in the counters of accumulated volume and operating time with power off is at least 10 years
  • The total average service life of the meters is 8 years
  • The devices are designed to measure the volume of liquid with parameters:
    • Working fluid temperature from +1 to +150 o C
    • Working fluid pressure up to 2.5 MPa (25 kgf/cm2)
    • The viscosity of the liquid is up to 2.0 cSt
  • The internal diameter of the pipeline is from 80 to 4000 mm.
  • The minimum measured flow rate (on pipes with an internal diameter of 80 mm.) is 2.7 m3/h
  • The maximum measured flow rate (on pipes with an internal diameter of 4000 mm.) is 452000 m3/h
  • Limits of permissible relative error in measuring volume and flow by pulse signal and indicator: ± 1.5%
  • Limits of the measured reduced error of flow measurement by Current signal: ± 1.5%
  • The length of the straight section in front of the acoustic transducers:
    • at least 5d (if a round knee, a fully open gate valve or a conical narrowing with an angle of no more than 30 o are located in front of them)
    • at least 10Du (in other cases)
  • The length of the straight section after the acoustic transducers is at least 2Du
  • The sensors have a pulse output signal (all versions), which can be transmitted as current pulses or removed from the optocoupler output, as well as a DC output signal proportional to the instantaneous flow rate (only DRC-3V). Signal Parameters:
    • Current
    • pulse duration - at least 250 ms
    • amplitude - (10 ± 3) mA
    • load capacity - no more than 500 ohms
      Optocoupler output
    • pulse duration - at least 250 ms
    • voltage in the output circuit - no more than 30 V
    • the value of the current pulse in the output circuit is not more than 100 mA

    • Parameters of the current output signal
    • 0-5 mA with a load resistance of no more than 2 kOhm
    • 4-20 mA with a load resistance of no more than 500 ohms
  • The DRK-3V devices are powered from an AC power supply with a voltage of (187... 242) V and a frequency of 50 ± 1 Hz. Consumed power not more than 20 VA
  • The DRK-3A and DRK-3B devices are powered from a stabilized DC source (11.5...15) V at a load of up to 500 mA. The resistance of the communication line is not more than 5 ohms per core
DOCUMENTATION

Price list

Questionnaire

All Floukor products

The group "New Technologies" offers for review the products of the plant Floukor: water flow meters, water meters, flow simulators, liquid flow converters, correlation vortex and low-consumption, water flow sensors, correlation
  • Water flowmeters (water meters) Floukor
    Water flowmeters (water meters)
    DRC-4A, DRC-4B, etc.
  • Flow simulators Floukor
    Flow simulators
    IR DRC et al .
  • Flow converters Floukor
    Flow converters
    DRC-B1, DRC-B2, DRC-B3, etc.
  • Water flow sensor Floukor
    Water flow sensor
    DRC-3, etc.

About Floukor

In the market of flowmeters since 1990. Development and production of ultrasonic correlation flow meters, vortex flow meters, as well as equipment for their verification.
  • COMMERCIAL ACCOUNTING

    Improving the quality of measurements. Reducing the need for expensive maintenance. Reducing the number of additional equipment. Long-term stability of measurements. Reduce downtime.
  • ACCURATE ACCOUNTING OF LIQUIDS

    Reduction of the measurement error. Lower maintenance costs. Improving the reliability of measurements. A wide range of measurements. No requirements for straight sections.
  • service

    Technical support, repair of devices, verification of devices, telephone consultations, visiting the enterprise to customers for prompt troubleshooting of possible problems

Information Board Floukor

Learn more about our products Floukor.
  • Price list изготовителя Флоукор
    Price list
  • Questionnaire от производителя Флоукор
    Questionnaire

NEW TECHNOLOGIES GROUP

For sales and support please contact